MTSeis_S is An Universal Audio Magneto-telluric Exploration system, which includes three coils, five non-polarized electrodes, 8-channel recorder and a calibration sub-system.

| Application Examples | Available S oftware | 
|---|---|
| Groundwater exploration | MTSeis_Data Plow | 
| Mining exploration | MTSeis_Data Processing | 
| Civil Engineering survey | IPI2win_MT (Free AP) | 
| Shallow geothermal exploration | ModEM (Resale of ModEM Geophysical Inc.) | 
| Seismoelectric observation | Passive & Active Seismic Source Tomography | 
| Earthquake research | CSEM 3D Tomography | 
| Recorder | Specifications | 
|---|---|
| ADC | 24 Bits x 8 channels | 
| 3G / 4G Internet connection | Optional with SMA for external Antenna | 
| WIFI AP | 802.11 b / g / n with SMA for external Antenna | 
| Sampling rate | 16KHz & 4KHz | 
| Geophone connection | Optional | 
| Power supply | Tri-paths : External, Hot-swappable 20AH x @7.2V & 5.2AH @7.2V backup  | 
| Dimension / Weight | 26.5 cm x 23.5 cm x 16 cm / 4.2 kg | 
| Frequency range | 8KHz ~ 0.1Hz | 
| Anti-aliasing filter | 8KHz | 
| Array Processing | Yes | 
| Interfaces | Ch1-Ch3 : M12 x8 for optional geophones Ch4-5 : M12 x8 for two electrode pairs Ch 6-8 : M12 x8 for three coils SMA x2 for Cellular modems ; SMA x2 for WIFI ; SMA x1 for GPS ; One SMA reserved M12x3 for External power RJ45 x2 for Ethernet  | 
| Non-polarized Electrodes | |
|---|---|
| Dimension / Weight | Φ10 cm x 15 cm/ 550 g | 
| V difference between two electrodes | < 1 mV | 
| Noise in 30 minutes | < 0.01 mV | 
| 24-hour stability | < 0.1 mV | 
| 30-days stability | < 1.0 mV | 
| Impedance | < 50 Ohm | 
| Frequency range | DC ~ 10 KHz | 
| Temperature range | -10 ~ 40oC | 
| Calibration Box | |
|---|---|
| Dimension / Weight | 21.5 cm x 18 cm x 9.5 cm/1 kg | 
| Sinusoidal signal Frequency | 8Hz using push button | 
| Voltage output to current electrodes | ~ 100mA | 
| Current output to coil | ~ 1mA | 
| Coil | |
|---|---|
| Dimension / Weight | Φ7 cm x 66 cm/ 6kg | 



MTSeis_S Array uses four simultaneously recording stations to de-spike the un-correlated noises by variance technique. The array includes one Calibration sub-system for calibrating at field site.
Red line : original
 Green line : noise removed for 114,000 seconds